We are looking for a data acquisition and recording system with 1600 bar rated pressure sensors, which can save the data as a file for downloading to a laptop via a USB port.
We would suggest the MulitCon which is a data recorder, indicator and sensor conditioning unit plus the DMP334 which is a high range pressure sensor with a 0 to 1600 bar range. The CMC-99 can be supplied inside a small enclosure with an IEC power socket on the side and a few cable glands for connecting the external pressure sensors.
MultiCon CMC-99 Multichannel Data Logger
- Part No: CMC-99-4-0-UI4-E-E-0B1
- Slot P – Power Supply: 85V…260V AC/DC
- Slot D – Interface Port: No Port (available for 0B1 option only)
- Slot C: 4 x voltage input + 4 x current input
- Slot B: Empty
- Slot A: Empty
- Extra Options: Front USB Host (IP40)
- Display: 3.5″ Graphic TFT, 16-bit colour touchscreen
- Transducer Power Supply: 24 V DC, +/-5% / 200 mA max.
- Communications interface: RS-485 (Modbus RTU), 1 x USB Host, USB Device
- Operating Temperature: 0 to +50°C
- Case Style: Panel Mount
- Case Dimension: 96 x 96 x 100mm
- Panel cut-out dimensions: 90.50 x 90.50mm
- Installation Depth: 102mm min.
- Internal Memory: Internal 1.5 GB, over 50 days (250,000,000 samples)
- Digital inputs: 1 x 24V DC, optocoupled
- Power Consumption: 15 VA typical; 20 VA max.
MultiCon CMC-99 License Key
- Part No: CMC-99 License Key
- Description: Datalogging license key
MultiCon CMC-99 Enclosure
- Part No: CMC-99 Enclosure
- Description: Instrumentation enclosure
DMP 334 High Pressure Transmitter
- Part No: 140-1604-1-3-100-V00-2-041
- Pressure Range: 0 – 1600 Bar G
- Output: 4 – 20mA / 2-wire
- Supply Voltage: 12 – 36V dc
- Electrical Connection: Male and female plug ISO 4400
- Process Connection: 9/16 UNF Internal Thread
- Process Connection Material: Stainless Steel 1.4542 (17-4PH)
- Seal Material: None (welded version)
- Diaphragm Material: Stainless Steel 1.4542 (17-4PH)
- Accuracy (NLH): 0.175% / Span (BFSL)
- IP Rating: 65
- Thermal Errors (TZS and TSS): ±0.025% FSO / °C
- Media Temperature: -40 to +140°C
- Operating Temperature: -25 to +85°C
- Special Options: None
- Approvals: None