Wireless pressure measurement kit for district heating monitoring use with a 5barg range plus a 1/4 BSP male fitting. Each pressure reading is transmitted wirelessly to a five channel base receiver, where it is converted to a 1-5Vdc or 4-20mA analogue output signal.
This IWPT wireless pressure monitoring package for use in district heating applications, comprises of two types of device, a battery powered wireless pressure sensor and a wireless base receiver.
The battery powered wireless pressure sensor consists of a pressure transducer module and signal conditioning electronics to measure pressure over the calibrated range of 0 to 5 bar g. The sensor is installed using a 1/4 BSP parallel male thread fitting and the pressure reading is transmitted using an inbuilt wireless transceiver. The pressure transducer module, signal conditioning and wireless transceiver are powered internally by a replaceable Lithium C cell battery.
Each transmitted pressure reading is collected using the five channel wireless receiver for pairing up to 5 wireless pressure sensor inputs and sending out 1-5Vdc or 4-20mA analogue outputs. A 5 amp rated alarm switch and LED indicator is also included for alerting a system or operator of missed transmissions or when a pressure threshold has been exceeded.
IWPT Wireless Pressure Sensing Kit
- SKU ID: s1-iwpt-125-21957
- Pressure Ranges: 5barg
- Wireless Receiver: five channel
- Output Signal: 1-5Vdc or 4-20mA user selectable
- Non-Linearity and Hysteresis: 0.25% FS
- Process Connection: 1/4 BSP male
- Optional Extras: 3dBI antenna for increased wireless range